1019h Synchronous Counter Overflow Value
Function
The value from which the Sync Counter is to begin counting anew is entered here. See chapter Synchronization object (SYNC).
Object description
Index | 1019h |
Object name | Synchronous Counter Overflow Value |
Object Code | VARIABLE |
Data type | UNSIGNED8 |
Savable | yes, category: communication |
Access | read / write |
PDO mapping | no |
Allowed values | |
Preset value | 00h |
Firmware version | FIR-v1426 |
Change history |
Firmware Version FIR-v1738-B501312: "Object Name" entry changed from "Synchronous counter overflow value" to "Synchronous Counter Overflow Value". Firmware version FIR-v1738-B501312: "Data type" entry changed from "UNSIGNED16" to "UNSIGNED8". |
Description
Allowed values: 02h to F0h and 0. If the value is "0", the sync message is transmitted as a CAN message with a data length of 0.