NP5 CANopen 在线手册

3323h Analogue Input Factor Denominator

Function

Value by which the read analog value (3220h+ 3321h) is divided before it is written in object 3320h.

Object description

Index 3323h
Object name Analogue Input Factor Denominator
Object Code ARRAY
Data type INTEGER16
Savable yes, category: application
Access read only
PDO mapping no
Allowed values
Preset value
Firmware version FIR-v1926-B648637
Change history

Value description

Subindex 00h
Name Number Of Analogue Inputs
Data type UNSIGNED8
Access read only
PDO mapping no
Allowed values
Preset value 02h
Subindex 01h
Name Analogue Input 1
Data type INTEGER16
Access read / write
PDO mapping no
Allowed values
Preset value 0001h
Subindex 02h
Name Analogue Input 2
Data type INTEGER16
Access read / write
PDO mapping no
Allowed values
Preset value 0001h

Description

The subindices contain:

  • Subindex 01h: Divisor for analog input 1
  • Subindex 02h: Divisor for analog input 2 (if present)