EtherCAT
Software connection
Tip: The following description assumes that an EtherCAT master from Beckhoff with the TwinCAT software is used.
- Connect the EtherCAT master to the controller, see .
- Supply the controller with voltage.
- Obtain the ESI file that corresponds exactly to the used firmware version from the following sources:
- From the Nanotec website us.nanotec.com. The current version of the firmware and the ESI file can be found in the Plug & Drive Studio download folder.
- From Nanotec support.
- Close the TwinCAT system manager if it is open.
- Then copy the ESI file to the TwinCAT subfolder:
- If you use TwinCAT version 2, use folder
<TWINCAT INSTALL DIR>/Io/EtherCAT
- If you use TwinCAT version 3, use folder
<TWINCAT INSTALL DIR>/3.1/Config/Io/EtherCAT
Example
Example: If TwinCAT 2 is installed on your computer under path C:\TwinCAT\
, copy the ESI file to pathC:\TwinCAT\Io\EtherCAT\
. - If you use TwinCAT version 2, use folder
- Open the ESI file with an editor. Find the AddInfo parameter. Enter:
- the value "2" if you would like to integrate the controller as Box (factory settings)
- the value "0" if you would like to integrate the controller as NC-Axis
- Now restart the TwinCAT system manager. The ESI files are read in again following a restart.
Note: 
The cycle time of the sync signal must always be set to 1 ms. You can set the bus cycle time (and, consequently, the interpolation time in 60C2h) to integer multiples of 1 ms.