PD6-E/-EB Modbus RTU Online Manual

6080h Max Motor Speed

Object description

Index 6080h
Object name Max Motor Speed
Object Code VARIABLE
Data type UNSIGNED32
Savable yes, category: drive
Access read / write
PDO mapping RX-PDO
Allowed values
Preset value
  • PD6-E891L95-E-65-5: 00007530h
  • PD6-E891L95-ES-65-5: 00007530h
  • PD6-EB80CD-E-65-5: 0000109Ah
  • PD6-EB80CD-ES-65-5: 0000109Ah
  • PD6-E891S95-E-65-5: 00007530h
  • PD6-E891S95-ES-65-5: 00007530h
  • PD6-E891M95-E-65-5: 00007530h
  • PD6-E891M95-ES-65-5: 00007530h
  • PD6-EB80SD-E-65-5: 00001004h
  • PD6-EB80SD-ES-65-5: 00001004h
  • PD6-EB80MD-E-65-5: 0000109Ah
  • PD6-EB80MD-ES-65-5: 0000109Ah
  • PD6-EB80LD-E-65-5: 000010CCh
  • PD6-EB80LD-ES-65-5: 000010CCh
Firmware version FIR-v1426
Change history

Firmware version FIR-v1614: "Savable" entry changed from "yes, category: application" to "yes, category: tuning".

Firmware version FIR-v1738-B501312: "Object Name" entry changed from "Maximum Speed" to "Max Motor Speed".

Firmware version FIR-v1738-B501312: "PDO mapping" table entry for subindex 00 changed from "no" to "RX-PDO".

Firmware version FIR-v1748-B538662: "Savable" entry changed from "yes, category: tuning" to "yes, category: drive".

Firmware version FIR-v1825-B577172: "Savable" entry changed from "yes, category: movement" to "yes, category: tuning".

Firmware version FIR-v1825-B577172: "Savable" entry changed from "yes, category: tuning" to "yes, category: drive".