3225h Analog Input Switches
Function
This object contains the value of the rotary switch that is used to configure the address of the controller . The switch position is only read during a restart one time.
Object description
Index | 3225h |
Object name | Analog Input Switches |
Object Code | ARRAY |
Data type | UNSIGNED16 |
Savable | no |
Access | read only |
PDO mapping | no |
Allowed values | |
Preset value | |
Firmware version | FIR-v1436 |
Change history |
Firmware version FIR-v1436: "PDO mapping" table entry for subindex 01 changed from "RX-PDO" to "TX-PDO". |
Value description
Subindex | 00h |
Name | Number Of Entries |
Data type | UNSIGNED8 |
Access | read only |
PDO mapping | no |
Allowed values | |
Preset value | 01h |
Subindex | 01h |
Name | Analog Input Switch #1 |
Data type | UNSIGNED16 |
Access | read only |
PDO mapping | TX-PDO |
Allowed values | |
Preset value | 0000h |
Description
If the controller is equipped with a rotary switch, the value of the rotary switch is displayed in subindex 01h. If the controller is equipped with two rotary switches, the value of the rotary switch is displayed in subindex 01h, which consists of switch 1 and 2.