202Ch MODBUS RTU Stop Bits
Function
This object contains the number of stop bits of the Modbus.
Object description
Index | 202Ch |
Object name | MODBUS RTU Stop Bits |
Object Code | VARIABLE |
Data type | UNSIGNED8 |
Savable | no |
Access | read only |
PDO mapping | no |
Allowed values | |
Preset value | 01h |
Firmware version | FIR-v1436 |
Change history |
Firmware version FIR-v1540: "Savable" entry changed from "yes, category: communication" to "no". Firmware version FIR-v1540: "Access" table entry for subindex 00 changed from "read/write" to "read only". |
Description
The number of stop bits is dependent on the parity, which can be set in object 202Dh.