3220h Analog Input Digits Function Displays the instantaneous values of the analog inputs in ADC digits. With object 3221h, the respective analog input can be configured as current or voltage input. Object description Index 3220h Object name Analog Input Digits Object Code ARRAY Data type INTEGER16 Savable no Access read only PDO mapping no Allowed values Preset value Firmware version FIR-v1426 Change history Value description Subindex 00h Name Number Of Analog Input Digits Data type UNSIGNED8 Access read only PDO mapping no Allowed values Preset value Subindex 01h Name Analog Input #1 Digit Data type INTEGER16 Access read only PDO mapping TX-PDO Allowed values Preset value Description Formulas for converting from [digits] to the respective unit: Voltage input: x digits * 10 V / 1023 digits Current input (if configurable): x digits * 20 mA / 1023 digits
3220h Analog Input Digits Function Displays the instantaneous values of the analog inputs in ADC digits. With object 3221h, the respective analog input can be configured as current or voltage input. Object description Index 3220h Object name Analog Input Digits Object Code ARRAY Data type INTEGER16 Savable no Access read only PDO mapping no Allowed values Preset value Firmware version FIR-v1426 Change history Value description Subindex 00h Name Number Of Analog Input Digits Data type UNSIGNED8 Access read only PDO mapping no Allowed values Preset value Subindex 01h Name Analog Input #1 Digit Data type INTEGER16 Access read only PDO mapping TX-PDO Allowed values Preset value Description Formulas for converting from [digits] to the respective unit: Voltage input: x digits * 10 V / 1023 digits Current input (if configurable): x digits * 20 mA / 1023 digits
Function Displays the instantaneous values of the analog inputs in ADC digits. With object 3221h, the respective analog input can be configured as current or voltage input.
Object description Index 3220h Object name Analog Input Digits Object Code ARRAY Data type INTEGER16 Savable no Access read only PDO mapping no Allowed values Preset value Firmware version FIR-v1426 Change history
Value description Subindex 00h Name Number Of Analog Input Digits Data type UNSIGNED8 Access read only PDO mapping no Allowed values Preset value Subindex 01h Name Analog Input #1 Digit Data type INTEGER16 Access read only PDO mapping TX-PDO Allowed values Preset value
Description Formulas for converting from [digits] to the respective unit: Voltage input: x digits * 10 V / 1023 digits Current input (if configurable): x digits * 20 mA / 1023 digits