N5 Modbus TCP 在线手册

321Dh Pre-control

Object description

Index 321Dh
Object name Pre-control
Object Code ARRAY
Data type UNSIGNED32
Savable yes, category: application
Access read only
PDO mapping no
Allowed values
Preset value
Firmware version FIR-v2213-B1028181
Change history

Value description

Subindex 00h
Name Number Of Entries
Data type UNSIGNED8
Access read only
PDO mapping no
Allowed values
Preset value 03h
Subindex 01h
Name Voltage Pre-control [‰]
Data type UNSIGNED32
Access read / write
PDO mapping no
Allowed values
Preset value 000003E8h
Subindex 02h
Name Acceleration Pre-control [‰]
Data type UNSIGNED32
Access read / write
PDO mapping no
Allowed values
Preset value 000003E8h
Subindex 03h
Name Velocity Pre-control [‰]
Data type UNSIGNED32
Access read / write
PDO mapping no
Allowed values
Preset value 000003E8h
▶   下一个